Z200 PVA

The Z200 PVA testing kit offers a comprehensive range of features designed to test and troubleshoot PV modules and arrays up to 1000V and 15A.
0.000 (CNY)

Description

The Z200 PVA PV testing kit offers a comprehensive range of features designed to test and troubleshoot PV modules and arrays . It allows you to measure the position of a single ground fault in a PV string with a Riso of less than 3 MΩ. Moreover, it can identify the position of a single disconnect in PV strings where Rs is greater than 10 kΩ. The Z200 PVA provides PV string impedance curves for health and degradation checks. It also calculates PV string series resistance (Rs), open circuit voltage (Voc), and short circuit current (Isc). The instrument is also equipped with a PV module voltage reader and a bypass diode checker to identify if an open or short circuit has occurred. It measures the shunting resistance (Rsh) to detect module or cell degradation. For periodic faults, an integrated timer is included. To aid in troubleshooting, a tone generator and tone tracer pickup are also incorporated. To ensure you have all the data you need, a built-in report generator provides reports in PDF, CSV, or JSON format. The instrument is operated over WiFi using a smartphone, tablet, PC, or MAC, providing flexibility and ease of use.

User info – download

Feature / functionZ200 PVA
Impedance test, frequency coverage100 Hz to 100 kHz
Impedance test, frequency accuracy+/- 2 %
Frequency drift with temperature (0 – 35 Celsius)>0.1
DC current test range0 – 15 A
DC voltage test range0 – 1000 V
Polarity checkYes
Measurement of resistance towards
ground (Riso)
Yes
Riso measurement range0 Ω – 40 MΩ
Riso measurement test conditionsIrradiation > 100 W and
m2 string VOC > 100V
Riso measurement precision (stable light conditions)+/- 50 kΩ +/- 10%
Riso measurement analysisAbove 40M Ω, Riso > 40M Ω
Below 100kΩ, Riso < 100kΩ
Threshold for localisation of an Riso ground fault3 MΩ
Localisation of an Riso ground fault precision (stable light conditions)+/- 0.5 PV module
Localisation of an Riso ground fault resolution0.1 PV modules
Localisation of singular series fault disconnectYes
Localisation of singular series fault precision+/- 1 PV module
Localisation of singular series fault resolution0.1 PV modules
Conditions for localisation of a singular series faultIrradiation > 100 W/m2
Tone generator to map out strings0 – 100 kHz
Amplifier probeIncluded
Wireless connection to controller deviceWiFi, use almost any web browser
EnclosureHPRC2300
String test time to complete60 seconds
Report functionsSingle PDF (CSV for String test)
Battery modelRCC-2054
Battery technologyLi-Ion, DC 15 V, 3200 mAh, 48.0 Wh
Operation time8-10 hours
Only registered users can write reviews